| Overview |
| Q. | What is the difference between a FT415 and a FT420? |
| A. | An FT415 has a battery for self-contained operation. The FT420 needs external power. |
| Q. | Can the FT415 be used with a standard flow sensor or flow meter? |
| A. | No, the "micro-power" option must be specified on the flow sensor. This means that the flow sensor or flow meter is equipped with a special pickup which draws a the least amount of current possible. Otherwise, the battery would run down in a matter of days. |
| Q. | What is the battery life? |
| A. | About three years under normal operation. |
| Q. | Can I use an FT415 to drive a chemical metering pump? |
| A. | Yes, it has a programmable pulse output for this purpose. |
|
|