Overview | Specifications | Download Manual

Q. What is the difference between a FT415 and a FT420?
A. An FT415 has a battery for self-contained operation. The FT420 needs external power.

Q. Can the FT415 be used with a standard flow sensor or flow meter?
A. No, the "micro-power" option must be specified on the flow sensor. This means that the flow sensor or flow meter is equipped with a special pickup which draws a the least amount of current possible. Otherwise, the battery would run down in a matter of days.

Q. What is the battery life?
A. About three years under normal operation.

Q. Can I use an FT415 to drive a chemical metering pump?
A. Yes, it has a programmable pulse output for this purpose.